Galaxy VXL UPS 500kW
- Up to 99% efficient in eConversion mode
- Maximize availability with modular, scalable architecture
- Live Swap: Third party verified module replacement with no scheduled downtime
- Unlock resiliency and sustainability with access to EcoStruxure software
- 1-year Secure NMC Subscription, allowing the customer to access future firmware updates, is included with purchase
Product Description
Galaxy VXL UPS 500kW Scalable to 1250kW, 400V, Start-up 5×8
Power outages a constant worry for your Lagos data center or critical operations? Breathe easy with the Galaxy VXL UPS 500kW, a robust and incredibly efficient 3-phase Uninterruptible Power Supply from the trusted experts at Schneider Electric. Built to handle the intense demands of modern IT and industrial environments right here in Nigeria, this powerhouse starts at 500kW and can effortlessly scale all the way up to a massive 1250kW. That’s serious power and future-proofing for your growing needs!
Imagine a UPS system that not only keeps your vital equipment running during blackouts but also saves you money on energy bills. The Galaxy VXL is designed for top-tier performance, offering exceptional reliability and energy efficiency that’s crucial for businesses in Lagos.
This advanced online double-conversion UPS works seamlessly with both reliable VRLA and cutting-edge Lithium-Ion batteries, giving you flexibility in choosing the best power backup for your specific requirements and budget. It handles a broad input voltage range (340–460V), common in our power grid, and ensures a super clean and stable power output with less than 1% harmonic distortion – meaning your sensitive equipment is always protected.
Monitoring and managing this powerful system is a breeze thanks to its intuitive touchscreen LCD interface. Plus, with USB compatibility and hot-swappable power modules, maintenance and future expansions are quick and cause minimal disruption to your operations.
The Galaxy VXL UPS isn’t just about power; it’s also about smart energy use. With a strong 100kW battery charger and compliance with major international standards like IEC 62040-1-1 and RoHS, you can be confident in its quality and safety. Schneider Electric’s commitment to sustainability shines through too – this UPS is designed with recyclable materials and a focus on reducing its environmental impact (a significant 322,800 kg eq. CO₂ reduction over its lifecycle!).
Whether you’re running a large data center in Ikeja, a vital healthcare facility in Victoria Island, a busy telecom hub in Abuja, or a critical manufacturing plant in Kano, the Galaxy VXL UPS 500kW (scalable to 1250kW) delivers the ultimate in uptime, scalability, and peace of mind.
Important Note: This is a special order item. Please call us for a personalized quote and to discuss lead times specific to your location in Nigeria.
| Lead time | Special Order – Call for Quoted Lead Times |
|---|
| Main Input Voltage | 400 V 3 phases 380 V 3 phases 415 V 3 phases |
|---|---|
| Main Output Voltage | 400 V 3 phases 380 V 3 phases 415 V 3 phases |
| Other Output Voltage | 400 V |
| Rated power in W | 500 kW |
| Rated power in VA | 500 kVA |
| Battery type | VRLA Li-Ion (Lithium-Ion) |
| Range of product | Galaxy VXL |
| Range compatibility | Galaxy VXL |
| Efficiency |
View Efficiency Graph
|
|---|---|
| Battery voltage | 480…576 V DC |
| Discharge battery voltage | 384 V DC |
| Maximum short-circuit current | 100 kA |
| Battery charger power | 100 kW full load |
| Max bypass input current | 729 A |
|---|---|
| Bypass current protection | 729 A |
| Number of power module | 4 |
| Number of power module free slots | 6 |
| Redundant | Yes |
| Product or component type | Uninterruptible power supply (UPS) |
| Colour | White |
|---|---|
| Height | 1970 mm |
| Width | 1200 mm |
| Depth | 1000 mm |
| Net weight | 851 kg |
| USB compatible | Yes |
| Network frequency | 40…70 Hz |
|---|---|
| Input voltage limits | 340…460 V 400 V |
| Maximum input current | 912 A |
| Max short time withstand current | 100 kA |
| Input harmonic distortion | Less than 3 % for full load |
| Load power factor | 0.5 leading to 0.5 lagging without derating |
| Maximum configurable power in W | 1250 kW |
|---|---|
| Harmonic distortion | < 3 % |
| Output frequency | 50…60 Hz |
| Crest factor | 3 |
| UPS type | Double conversion online |
| Wave type | Sine wave |
| Output harmonic distortion | < 1% linear load and < 5% non-linear load |
| Output overload operation | 10 minutes at 125% and 60 seconds at 150% |
| Bypass type | No bypass |
| Maximum configurable power in VA | 1250 VA |
| Product certifications | IEC 62040-1-1 IEC 62040-2 IEC 62040-3 VFI-SS-111 RoHS |
|---|---|
| Standards | IEC 60721-4-2 level 2M2 |
| Ambient air temperature for operation | 0…40 °C |
|---|---|
| Relative humidity | 5…90 % non-condensing |
| Operating altitude | 0…3000 m |
| Ambient air temperature for storage | -25…55 °C |
| Storage Relative Humidity | 0…95 % non-condensing |
| Heat dissipation | 47782 Btu/h |
| IP degree of protection | IP20 |
| control panel | Touch screen LCD user interface |
|---|
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 215 cm |
| Package 1 Width | 141 cm |
| Package 1 Length | 116 cm |
| Package 1 Weight | 714 kg |
| Warranty | 1 year on-site repair or replace with factory authorized Start-Up |
|---|







